TI-85 Link Protocol Guide v1.0 - System Backup Transfers


System Backup Transfers

A System Backup is one large transmission containing all user-modifiable data in the calculator. The file format that the TI-85 Graph Link software uses can be found in the file formats section of this documentation.

The protocol for all system backup transfers is shown below. For information on packet formats, click here.

A computer can be either the sending unit or the receiving unit.

Step Direction Packet

1

Sending Unit

===>

Receiving Unit

VAR with backup-style header and type ID = 0x1D.

2

<===

ACK

3

<===

CTS or SKIP/EXIT. If exit, do step 4 and quit.

4

===>

ACK

5

===>

DATA - section 1 (system data)

6

<===

ACK

7

===>

DATA - section 2 (user data)

8

<===

ACK

9

===>

DATA - section 3 (variable table?)

10

<===

ACK

Example (PC sending backup to TI):
PC: 05 06 09 00 B1 08 1D B3 19 DA 00 F7 8B FE 03 Variable header: Backup
TI: 85 56 09 00 Acknowledgement of header
  85 09 09 00 Clear to send backup
PC: 05 56 00 00 Acknowledgement of CTS
  05 15 B1 08 <8B1h bytes of data plus checksum> Backup data section 1 (system data)
TI: 85 56 B1 08 Acknowledgement of data
PC: 05 15 B3 19 <19B3h bytes of data plus checksum> Backup data section 2 (user data)
TI: 85 56 B3 19 Acknowledgement of data
PC: 05 15 DA 00 <DAh bytes of data plus checksum> Backup data section 3 (variable table?)
TI: 85 56 DA 00 Acknowledgement of data
PC: 05 92 00 00 End Of Transmission (if PC sending)
For PC receiving backup from TI, swap 05 & 85 IDs.